Rated voltage range: 10 to 100 and 160 to 400V General specifications: Operating temperature range: -40 to +105 and -25 to +105 degrees Celsius Capacitance tolerance (25 degrees Celsius, 120Hz): 0 to 20% Leakage current (uA): 0.02CV or 5mA, whichever is smaller (at 25 degrees Celsius, after 5 minutes) C: nominal capacitance (uF), V: rated voltage (V) Temperature stability (120Hz): capacitance change 10 to 100V DC: capacitance at -40 degrees Celsius shall not be less than 60% of the 25 degrees Celsius value 160 to 400V DC: capacitance at -25 degrees Celsius shall not be less than 70% of the 25 degrees Celsius value Load life (+105 degrees Celsius): time: 2,000 hours Leakage current: not more than the specified value Capacitance change: within +(-)20% of the initial value Dissipation factor: not more than 200% of the specified value Shelf life (+105 degrees Celsius): time: 2,000 hours Leakage current: not more than the specified value Capacitance change: within +(-)20% of the initial value Dissipation factor: not more than 200% of the specified value After test: UR to be applied for 60 minutes, 24 to 48 hours before measurement Product Certifications:
Certificate Standard:SGS
Certificate Number:GZSCR041248032/LP
Issue Date:24-Dec-2004
Certification Agent: SGS-CSTC Ltd
Certificate Standard:UL
Certificate Number:E166700/03CA23659
Issue Date:15-Sep-2003
Certification Agent: Underwriters Laboratories Inc.
Certificate Standard:VDE
Certificate Number:40012049
Issue Date:27-Oct-2004
Certification Agent: VDE Testing and Certification Institute
Certificate Standard:RoHS
Certificate Number:CQC06130017473
Issue Date:08-Sep-2006
Expiry Date:07-Sep-2007
Certification Agent: China Quality Certification Centre